RXR-MC100BGD Explosion-Proof 4WD Firefighting Robot
Product Overview
RXR-MC100BGD is an electric four-wheel-drive firefighting and reconnaissance robot developed for remote operations in hazardous industrial environments. It combines a remotely aimed water cannon with live imaging, thermal sensing and gas monitoring to support emergency response teams while reducing the need for direct personnel entry.
The platform is designed for chemical facilities, oil and gas sites, industrial plants and other controlled emergency-response scenarios. Its suitability for any classified hazardous area must be reviewed against the specific unit’s certificates and the site’s safety requirements.
Product Video
Watch the RXR-MC100BGD firefighting robot demonstration to see its remotely operated chassis, firefighting equipment and operational concept. Final water-cannon performance and hazardous-area suitability depend on the delivered configuration and site conditions.
Key Features
Electric 4WD Remote Mobility
Remote-controlled travel on industrial terrain to position the firefighting equipment away from the operator.
Water Cannon & Self-Cooling
Remote aim and pitch control, high-output water delivery and built-in spray cooling for demanding environments.
Thermal Imaging & Video
A pan-tilt monitoring platform and thermal imaging help assess fire conditions and visibility-limited areas.
Six-Gas Monitoring
Manufacturer lists monitoring for O2, CO2, CO, H2S, CH4 and NH3 as part of its hazard reconnaissance equipment.
Application Areas & Deployment Scenarios
Industrial Fire Suppression
Remote water-cannon positioning for emergency response in industrial facilities and high-risk process areas.
Oil, Gas & Chemical Facilities
Support for incident reconnaissance and firefighting where smoke, heat or hazardous gases increase personnel exposure.
Remote Monitoring & Hazard Assessment
Visual and thermal observation, gas sensing and operator-led assessment before entering restricted areas.
Outdoor Emergency Operations
Four-wheel-drive mobility for suitable outdoor routes, with terrain, water supply and communications checked on site.
Firefighting System & Deployment Requirements
This is an operator-controlled industrial emergency-response system. A qualified team must evaluate the operating environment, water or foam supply, hose connection, wireless range, obstacle clearance, explosion-risk zoning, thermal exposure and emergency recovery procedure before deployment.
Operational Readiness
• Confirm pressure, fire-water/foam supply and access routes.
• Verify communications under actual buildings and site obstructions.
• Review remote control, thermal imaging, gas detectors and self-cooling.
• Establish safe-area procedures, trained operators and recovery plans.
Key Technical Data
*Manufacturer-published figures under stated or suitable conditions; confirm supplied model version.
Technical Specifications
| Model | RXR-MC100BGD |
|---|---|
| System type | Electric four-wheel-drive firefighting and reconnaissance robot |
| Dimensions (L × W × H) | 2080 × 1200 × 1280 mm |
| Unit weight | Approx. 1200 kg (not shipping gross weight) |
| Travel speed | 0–1.8 m/s (manufacturer-listed) |
| Climbing capability | Approx. 35° (manufacturer-listed) |
| Remote-control range | Up to 1000 m in suitable open conditions |
| Operating time | Up to 4 hours (manufacturer-listed configuration) |
| Water-cannon flow | 100 L/s (manufacturer-listed configuration) |
| Water-cannon working pressure | 1.0–1.6 MPa |
| Water spray reach | Over 95 m (manufacturer-listed; water supply dependent) |
| Thermal imager | Included in manufacturer-described configuration |
| Gas detection | O2 / CO2 / CO / H2S / CH4 / NH3 |
| PTZ observation | 360° horizontal reconnaissance |
| Cooling | On-board self-spray cooling system |
| Water ingress protection | IP67 chassis; IP65 upper electronics (manufacturer-stated) |
| Explosion-proof requirements | Check the unit-specific Ex certificate, marking and site hazardous-area classification |
Specifications are manufacturer-published and may differ by configured version. Explosion-proof markings differ across published sources; obtain the exact certificate and rating for the serial-numbered delivered unit before hazardous-area deployment.
Frequently Asked Questions
Is the robot autonomous?
The published configuration is primarily remotely operated. Do not assume autonomous navigation or intervention without confirming optional equipment.
Can the robot be used in an explosive atmosphere?
The product is marketed with an explosion-proof design. Suitability depends on the installed configuration, matching Ex certification and the classification of the intended site. Obtain the exact certificate before deployment.
Does it include thermal imaging and gas detection?
The manufacturer describes a thermal imager and six-gas detection. Confirm sensor package, calibration support and delivered bill of materials before ordering.
Is the 1,000 m operating distance guaranteed?
No. It is a manufacturer-stated range under suitable conditions; real sites may have radio interference, obstructions and reduced visibility.
Does the quoted weight include packaging?
No. Approximately 1,200 kg is the published equipment weight. Confirm crate dimensions and gross shipping weight for freight planning.
Discuss Your Project Requirements
Tell us about the industry, hazardous-area classification, fire-water supply, site access, operating distance and required detection functions. Robotmall can help review the suitable configuration, sourcing and deployment planning.
Request a Quote & ConsultationAbout robotmall
robotmall is a global B2B robotics solutions platform connecting manufacturers, technology partners and businesses worldwide. We support solution evaluation, sourcing, deployment coordination and post-deployment services through Robot.icu.

- Drive System:
- Electric 4WD
- Remote Control:
- Up to 1000 m manufacturer rating
- Monitoring:
- Thermal imaging and six-gas detection
- Firefighting System:
- Remotely directed water cannon
- Protection:
- IP67 chassis / IP65 upper electronics
- Hazardous Area:
- Unit-specific explosion-proof certification required